THE OP AMP PEAK DETECTOR

Square, triangular, sawtooth, and pulse waves are typical examples of nonsinusoidal waveforms. A conventional ac voltmeter cannot be used to measure these nonsinusoidal waveforms because it is designed to measure the RMS value of the pure sine wave. One possible solution to this problem is to measure the peak values of the nonsinusoidal waveforms.


circuit diagram op amp peak detector





Figure shows the Circuit Diagram of a PEAK DETECTOR that measures the Positive peak values of the Square wave input. During the positive half-cycle of Vin, the output of the op amp drives D1 on, charging capacitor C to the positive peak value Vp of the input voltage Vin. Thus, when D1 is forward biased, the OP AMP operates as a voltage follower. On the other hand, during the negative half-cycle of Vin, diode D1 is reverse biased, and voltage across C is retained. The only discharge path for C is through Rl since the input bias current Ib is negligible. For proper operation of the circuit, the charging time constant (CRd) and discharging time constant (CRl) must satisfy the following conditions:

op amp peak equation
where,
Rd= Resistance of the Forward biased diode, typically 100Ω
T=time period of the input waveform.

And

equation peak detector

where Rl is the load resistor.


input and output waves peak op amp

Figure shows the input and output waveform of Peak Detector using OP AMP 741